# cbAppColdStart()

## Explanation

`cbAppColdStart(bool_t bStart)` is called first on `bStart == FALSE` and then on `bStart == TRUE`. The `bStart == TRUE` clause is used to initialize the application.

This is where the important initialisation of the TWELITE NET (the [`sToCoNet_AppContext`](/en/twelite-net-api-ref/gou-zao-ti/stoconet_appcontext.md) structure) needs to be done. Some features can only be configured here.

User-defined event processing functions are registered with the [`ToCoNet_Event_Register_State_Machine`](/en/twelite-net-api-ref/yzaibento/toconet_event-api/toconet_event_register_state_machine.md)`()` function.

At the end of this process, the [`ToCoNet_vMacStart()`](/en/twelite-net-api-ref/twelite-net-guan-shu/toconet_vmacstart.md) function is called.

The start of the MAC layer is explicitly stated as a procedure in the API.

## Arguments

| Type     | Name     | Remark                                                                              |
| -------- | -------- | ----------------------------------------------------------------------------------- |
| `bool_t` | `bStart` | It is called twice at startup, the first time as FALSE and the second time as TRUE. |

#### bStart

`FALSE`: It is just after the start of microcomputer, and initialization of peripherals etc. has not been done. Call the [`ToCoNet_REG_MOD_ALL()`](broken://pages/-LB-k-KjxdeixZFXN5c7) macro of module registration here.

`TRUE`: TWELITE NET Called after the library and hardware APIs have been initialized, but before the library is initialized. The following procedure is described here.

* Setting initial parameters for [`sToCoNet_AppContext`](/en/twelite-net-api-ref/gou-zao-ti/stoconet_appcontext.md) structure
* Resister a state machine by [`ToCoNet_Event_Register_State_Machine()`](/en/twelite-net-api-ref/yzaibento/toconet_event-api/toconet_event_register_state_machine.md)&#x20;
* Initialisation of the application's own memory area etc.
* Hardware initialisation
* Starts MAC layer by[`ToCoNet_vMacStart()`](/en/twelite-net-api-ref/twelite-net-guan-shu/toconet_vmacstart.md)&#x20;

## Returns

None

## Sample code

```c
void cbAppColdStart(bool_t bAfterAhiInit)
{
	if (!bAfterAhiInit) {
		// before AHI init, very first of code.

		// Register modules
		ToCoNet_REG_MOD_ALL();

	} else {
		// disable brown out detect
		vAHI_BrownOutConfigure(0,//0:2.0V 1:2.3V
				FALSE,
				FALSE,
				FALSE,
				FALSE);

		// clear application context
		memset (&sAppData, 0x00, sizeof(sAppData));
		sAppData.u8channel = CHANNEL;

		// ToCoNet configuration
		sToCoNet_AppContext.u32AppId = APP_ID;
		sToCoNet_AppContext.u8Channel = CHANNEL;

		sToCoNet_AppContext.bRxOnIdle = TRUE;

		// others
		SPRINTF_vInit128();

		// Register
		ToCoNet_Event_Register_State_Machine(vProcessEvCore);

		// Others
		vInitHardware(FALSE);

		// MAC start
		ToCoNet_vMacStart();
	}
}
```


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://sdk.twelite.info/en/twelite-net-api-ref/krubakku/cbappcoldstart.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.